• Facebook
  • Linkedin
  • Twitter
  • Youtube
  • Shop
  • My Account
  • Checkout
  • Basket
  • 0Shopping Cart
Real Laboratory
  • Home
    • About us
  • Products
    • Sample collection & preservation
      • Saliva
      • Stool
      • Microbiome
      • Tissues and Cells
    • Molecular Biology
      • DNA isolation
      • RNA isolation
      • Microbiome
      • DNA Clean Up
      • Reagents
    • Microbiology
      • Parasitology
      • COVID-19
  • Resources
    • Sample Collection
    • Molecular Biology
    • Microbiology
  • Distributors
  • News
  • Contact Us
  • Search
  • Menu
Virus transport and preservation medium . COVID 19 Detection

Recent Posts

  • New REAL Molecular Biology Product Guide
  • Covid19 rapid test for healthcare professionals
  • Transport of saliva samples and other cares
  • Rapid COVID 19 test from blood, serum or plasma
  • Solutions to detect coronavirus in laboratories

Categories

  • Home
  • Microbiology

Virus transport and preservation medium (Inactivated)

SKU: YMJTE2 Categories: All Products, COVID-19, Destacados, Microbiology, Saliva, Sample Collection and Preservation Tags: covid-19, preservation, sample, transport, virus
  • Description
  • Reviews (0)

Description

Transport and preservation medium for virus, Chlamydia ,mycoplasma and Ureaplasma sample. Avoid aerosol infection.

Details

biocomma® Virus Transport and Preservation Medium is intended for the collection, storage and transport of clinical viruses, chlamydiae, mycoplasma, or ureaplasma specimens from the collection site to the testing laboratory.

Applications:

Applicable for the collection and transportation of clinical flu, avian flu, HFMD, measles and other virus samples as well as mycoplasma, ureaplasma, chlamydia and other samples.

Required Materials But Not Provided:

Materials required for isolation, extraction and culture of viruses, chlamydiae, mycoplasma and ureaplasma.

Process:

  • Write the sample information on the sticker before sampling.
  • According to the experiment purpose, use the swab to collect samples from corresponding parts
  • Put the swab back into the preservation solution immediately after sampling, break the swab rod and screw the lid tightly.
  • When collect specimens with biocomma® Inactivated Transport and Preservation Medium,tube can be transported to the laboratory at room temperature (5-25℃) within 7 days. Avoid repeated freeze-thaw cycles. For best performance, complete testing within 24 hours in controlled temperature environment.
  • The specific sampling method:
    a)   Nasal swab: insert the swab head gently into the nasal palate of the nasal canal, stay for a while, then slowly rotate out. Swab the other side of the nostril with another swab, dip the swab head into the preservation solution, break the swab rod and discard the upper rod.(suitable for sampling with this product)
    b)   Throat Swab: swab the bilateral pharyngeal tonsils and posterior pharyngeal wall, dip the swab head into the preservation solution, break the swab rod and discard the upper rod. (suitable for sampling with this product).

Limitations :

biocomma® Transport and Preservation Medium is intended to be used with the medium tubes and swabs provided in the kit. The use of tubes of medium or swabs from any other source could affect the performance of the product.

Notices:

  • Please read this instruction carefully before use.
  • biocomma® Transport and Preservation Medium should be used by trained and qualified personnel.
  • Do not use beyond expiration date. Do not use if the original seal of the medium and swab is damaged. Check the outer packaging of the product before use to make sure it is complete with no content overflow. The labeling is unbroken with clear content and no shedding. The preservation solution should be pre-loaded in the sampling tube. It is normal phenomenon to have precipitate at low temperature. Biocomma Inactivated Transport and Preservation Medium is a clear solution, do not use if the color of the medium turned turbid, or cloudy; Biocomma Inactivated Transport and Preservation Medium is an orange-red color solution, do not use if the color of the medium has changed from light orange-red.
  • Avoid the medium in contact with eyes and skins.
  • Do not contaminate the tip of the swab before taking samples.
  • Be careful when the swab is inserted into the mouth for oral sampling. Avoid the risk of choking.
  • For single use only. Different patients are prohibited from using the same swab or tube.
  • Specimens for the search of viruses, chlamydiae and ureaplasmas involves risk of infection, and must be collected and handed using proper PPE against biological risk according to published guidelines and local regulations.
  • Sample sites, condition, volume and timing of specimen collected are significant variables in obtaining reliable culture results. Follow recommended guidelines for specimen collection.
  • The use of this product in combination with diagnostic kits or instruments must be validated by the user prior to use.

Storage:

For optimal performance, the product must be stored in its original package at 5-25°C until the time of use.  Do not expose to excessive heat or direct sunlight prior to use.

Waste Disposal:

Waste must be disposed of in compliance with local legislation.  If necessary, take appropriate precautions for infected material.

Order Informations:

Ref: YMJ-TE1               Inactivated virus sampling tube(10 mL), containing 3 mL preservation medium (Inactivated), 1* PP fiber swabs3 mL/pcs, 50pc/Box

Flyer
Protocol
CE

Reviews

There are no reviews yet.

Be the first to review “Virus transport and preservation medium (Inactivated)” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

  • ALL TEST.- COVID19 Rapid Test

    Read more Show Details
  • REAL Spin Viral RNA Kit

    Read more Show Details
  • BTD4 Centrifuge

    Read more Show Details
  • REAL Saliva Microbiome Sample Collection Kit

    Read more Show Details

Schedule

Monday to Friday: 8:30 – 17:00

Address

Leonardo Da Vinci, 10
Valencia Technology Park
46980 Paterna, Valencia, SPAIN

Real Laboratory SL

info@reallaboratory.com
Teléfono: +34 96 136 61 07
Fax: +34 96 136 61 68

Information

General conditions
Standards and privacy ( LOPD )

© Copyright - Real is a Registered Trademark of Durviz S.L.U. All rights reserved. - 2016 - Web design by B2B activa.
  • Facebook
  • Linkedin
  • Twitter
  • Youtube
  • Home
  • Products
  • Resources
  • Distributors
  • News
  • Contact Us
ALL TEST.- COVID19 Rapid Test REAL Saliva Viral Sample Collection Kit
Scroll to top